Skip to Content
VANTEQINDUSTRIAL
Instrumentation / TM-240

Series TM-240 Resistance Thermometer

VQ-TM240

Temperature instrument, range -50 to +400 °C, accuracy Class A to IEC 60751.

RANGE
-50 to +400 °C
ACCURACY
Class A to IEC 60751
INSERTION
50 to 1,500 mm
CONNECTION
G 1/2, clamp or flanged

Why it is specified

The thermowell decides the response time and the thermometer only reports it. Both are quoted together with the insertion length worked out from the pipe, not guessed from the catalogue.

Typical applications

  • Bearing temperature on pump sets
  • Heat exchanger monitoring
  • Steam line monitoring
  • Vessel and line temperature

Options and executions

  • Calibration certificate at three points
  • Duplex sensor element
  • Tapered thermowell for high velocity
  • Two-wire transmitter in the head
Specification

The full table.

Figures cover the whole series. The variant table below narrows them to a part number.

PERFORMANCE

Measuring range
-50 to +400 °C
Accuracy
Class A to IEC 60751
Response time
4 to 20 seconds in water
Output or indication
Pt100 three or four wire, or 4 to 20 mA

MATERIALS

Wetted parts
1.4404 stainless steel sheath
Head or case
Aluminium head, epoxy coated
Insulation
Mineral oxide
Seal
Spring loaded, into a thermowell

CONNECTIONS AND RATINGS

Process connection
G 1/2, clamp or flanged
Insertion length
50 to 1,500 mm
Pressure rating
PN40
Ambient temperature
-40 to +85 °C
Protection
IP66
Variants and part numbers

Stocked frame sizes.

PART NUMBERRANGEINSERTIONCONNECTIONOUTPUT
VQ-TM240-10-50 to +200 °C100 mmG 1/2Pt100
VQ-TM240-200 to 300 °C300 mmClamp4 to 20 mA
VQ-TM240-300 to 400 °C800 mmFlanged4 to 20 mA
Datasheet

TM-240, DS-TM-240

  • Document DS-TM-240
  • Revision Rev 2
  • Issued 2026
  • Pages 8

The datasheet is issued with the selection rather than downloaded blind, so the figures that arrive are the ones for your duty point. Ask for it with the quotation and it comes back as a PDF.

What is in it

  • Selection data and the limits each figure applies at
  • Dimensional drawings for every size in the variant table
  • Materials of construction and the compatibility notes
  • Installation, commissioning and maintenance intervals
  • Spare parts list with the part numbers
Next step

Quote the TM-240 for your duty.

Send the process data and the line size. The quotation comes back with the selection, the calculation and the lead time on the stocked variants.

Vanteq Industrial is a fictional company created for demonstration purposes. This product does not exist. The specifications, performance figures, materials and datasheet references on this page are illustrative and must not be used to select, size or buy equipment.