Seal support system, volume Not applicable, circulating, pressure 25 bar.

VOLUME
Not applicable, circulating
PRESSURE
25 bar
TEMPERATURE
-20 to +260 °C
PLAN
Plan 23, closed circuit

Why it is specified

A double seal without a barrier system is a double seal that fails twice. The pot, the tubing, the cooling coil and the instrumentation are quoted as one assembly against the seal it serves.

Typical applications

  • Agitator seal support
  • Double seals on aggressive duty
  • Hot oil circulation seals
  • Hygienic double seals

Options and executions

  • Level switch with a contact
  • Nitrogen regulator panel
  • Pre-piped and tested as an assembly
  • Pressure switch with a contact
Specification

The full table.

Figures cover the whole series. The variant table below narrows them to a part number.

PERFORMANCE

Reservoir volume
Not applicable, circulating
Vessel design pressure
25 bar
Cooling capacity
2 to 18 kW to cooling water

MATERIALS

Vessel
1.4404 stainless steel shell
Tubing and fittings
1.4404 coil, 10 m
Cooling coil
1.4404 in a water jacket
Seals
Graphite

CONNECTIONS AND RATINGS

Seal connections
Two off G 1/2 to the seal chamber
Instrument ports
Temperature and vent
Design temperature
-20 to +260 °C
Flush plan
Plan 23, closed circuit
Mounting
Bracket on the pump
Variants and part numbers

Stocked frame sizes.

PART NUMBERVOLUMEPRESSUREPLANINSTRUMENTATION
VQ-SS310-102 kW25 barPlan 23, closed circuitThermometer pocket
VQ-SS310-208 kW25 barPlan 23, closed circuitThermometer pocket
VQ-SS310-3018 kW25 barPlan 23, closed circuitThermometer and flow switch
Datasheet

SS-310, DS-SS-310

  • Document DS-SS-310
  • Revision Rev 3
  • Issued 2026
  • Pages 10

The datasheet is issued with the selection rather than downloaded blind, so the figures that arrive are the ones for your duty point. Ask for it with the quotation and it comes back as a PDF.

What is in it

  • Selection data and the limits each figure applies at
  • Dimensional drawings for every size in the variant table
  • Materials of construction and the compatibility notes
  • Installation, commissioning and maintenance intervals
  • Spare parts list with the part numbers
Next step

Quote the SS-310 for your duty.

Send the process data and the line size. The quotation comes back with the selection, the calculation and the lead time on the stocked variants.